Versatile Fuse/Breaker Panel, 6/6 Versa-Slots, 5/5 GMT, 2 Hole Lug Input/Output, Power/Fuse Fail Alarm, Bus Display Switch, 12 TFD's Included
Part #: 7873001211-A
Bus Rating:
425 Amps
425 Amps
Number of Positions:
6 Versa-Slots + 5 GMT's/Side (This panel includes 12 TFD Holders.)
6 Versa-Slots + 5 GMT's/Side (This panel includes 12 TFD Holders.)
Max Fuse/Breaker:
TLS Fuse-125A, TPC Fuse-125A, TPS Fuse-70A, GMT Fuse-15A, 1 Pole Breaker-100A, 2 Pole Breaker-150A
TLS Fuse-125A, TPC Fuse-125A, TPS Fuse-70A, GMT Fuse-15A, 1 Pole Breaker-100A, 2 Pole Breaker-150A
Mechanical | |
Dimensions | 19 In. [482.6mm] W x 5.25 In. [133.35mm] H x 10.79 In. [274.1mm] D |
Rack Spaces | 3U |
Mounting | Universal, 19 or 23 Inch, WECO or EIA |
Offset MTG Positions | Flush, 3.5 In. Offset |
Finish | Black Textured Powder Coat |
Packaging | |
Packaged Width | 21In. [53.34cm] |
Packaged Length | 24 In. [60.96cm] |
Packaged Depth | 12 In. [30.48cm] |
Electrical | |
Nominal Voltage | -/+24-48V DC |
Voltage Range | -/+19-60V DC |
Number of Buses | 2 |
Bus Rating | 425 Amps |
Max. Interrupt Device | 500 Amps |
Number of Positions | 6 Versa-Slots + 5 GMT's/Side (This panel includes 12 TFD Holders.) |
Max Fuse/Breaker | TLS Fuse-125A, TPC Fuse-125A, TPS Fuse-70A, GMT Fuse-15A, 1 Pole Breaker-100A, 2 Pole Breaker-150A |
Max Continuous Load | TLS Fuse-100A, TPC Fuse-100A, TPS Fuse-56A, GMT Fuse-10.5A, 1 Pole Breaker-80A, 2 Pole Breaker-120A |
Power Dissipation (Fully Loaded) | 110 Watts max |
Fuse/Breaker Type | TLS, TPC, TPS, and GMT Fuses, 1 and 2 Pole Breakers |
Extras | |
Load Sharing | NO |
Filtered | NO |
Volt/Current Meter | YES |
Connections | |
Input Type | 2 Hole Compression Lugs, 3/8 In. Stud x 1 In. Spacing |
Input Wire Range | Up to 750 kcmil |
Max. Terminal Width | 1.625 In. Max |
Output Type | Versa-Slot: 2 Hole Compression Lugs, 1/4 In. Stud x 5/8 In. Spacing, GMT: Barrier Strip |
Output Wire Range | Versa-Slot: Up to 2/0 AWG, GMT: 10 to 22 AWG |
Max. Terminal Width (Output) | Versa-Slot: 0.640 In. max, GMT: 0.312 In. max |
Chassis Ground Type | 2 Hole Compression Lugs, 1/4 In. Stud x 5/8 In. Spacing |
Ground Wire Range | Up to 2 AWG |
Environmental | |
Short Term. Op. Temp | -40° C to 65° C |
Max. Ambient | Up to 65° C |
Storage Temperature | -40° C to +70° C |
Humidity Range | 0 to 95% non-condensIng |
Alarming | |
Alarm Indicators | Green (Power)/Red (Alarm) |
Alarm Functions | Form C Relay Contacts for Remote Fuse and Power Fail Indication, Bus Display Switch for Local Display Only |
Connection Type | Solderless Wire Wrap (18 to 30 AWG) |
Alarm Rating | DC 30W/AC 50VA |
Standards | |
Safety Type | Listed |
Safety Approvals | UL 60950-1/UL 1801/CSA C22.2 No.60950-1/EN 60950-1/IEC 60950-1 |
Telcordia Approvals | NEBS Level 3 (GR-63/GR-1089) |
CLEI Code | PWPYADBRRA |
Downloads | |
Datasheet | 7873001211-A.pdf |
Installation Manual | INS-787XXXXXXX.pdf |
Description
2 Hole Lug Input/Output, Power/Fuse Fail Alarm, Bus Display Switch, 12 TFD's Included, Learn More…
Specification
Mechanical | |
Dimensions | 19 In. [482.6mm] W x 5.25 In. [133.35mm] H x 10.79 In. [274.1mm] D |
Rack Spaces | 3U |
Mounting | Universal, 19 or 23 Inch, WECO or EIA |
Offset MTG Positions | Flush, 3.5 In. Offset |
Finish | Black Textured Powder Coat |
Packaging | |
Packaged Width | 21In. [53.34cm] |
Packaged Length | 24 In. [60.96cm] |
Packaged Depth | 12 In. [30.48cm] |
Electrical | |
Nominal Voltage | -/+24-48V DC |
Voltage Range | -/+19-60V DC |
Number of Buses | 2 |
Bus Rating | 425 Amps |
Max. Interrupt Device | 500 Amps |
Number of Positions | 6 Versa-Slots + 5 GMT's/Side (This panel includes 12 TFD Holders.) |
Max Fuse/Breaker | TLS Fuse-125A, TPC Fuse-125A, TPS Fuse-70A, GMT Fuse-15A, 1 Pole Breaker-100A, 2 Pole Breaker-150A |
Max Continuous Load | TLS Fuse-100A, TPC Fuse-100A, TPS Fuse-56A, GMT Fuse-10.5A, 1 Pole Breaker-80A, 2 Pole Breaker-120A |
Power Dissipation (Fully Loaded) | 110 Watts max |
Fuse/Breaker Type | TLS, TPC, TPS, and GMT Fuses, 1 and 2 Pole Breakers |
Extras | |
Load Sharing | NO |
Filtered | NO |
Volt/Current Meter | YES |
Connections | |
Input Type | 2 Hole Compression Lugs, 3/8 In. Stud x 1 In. Spacing |
Input Wire Range | Up to 750 kcmil |
Max. Terminal Width | 1.625 In. Max |
Output Type | Versa-Slot: 2 Hole Compression Lugs, 1/4 In. Stud x 5/8 In. Spacing, GMT: Barrier Strip |
Output Wire Range | Versa-Slot: Up to 2/0 AWG, GMT: 10 to 22 AWG |
Max. Terminal Width (Output) | Versa-Slot: 0.640 In. max, GMT: 0.312 In. max |
Chassis Ground Type | 2 Hole Compression Lugs, 1/4 In. Stud x 5/8 In. Spacing |
Ground Wire Range | Up to 2 AWG |
Environmental | |
Short Term. Op. Temp | -40° C to 65° C |
Max. Ambient | Up to 65° C |
Storage Temperature | -40° C to +70° C |
Humidity Range | 0 to 95% non-condensIng |
Alarming | |
Alarm Indicators | Green (Power)/Red (Alarm) |
Alarm Functions | Form C Relay Contacts for Remote Fuse and Power Fail Indication, Bus Display Switch for Local Display Only |
Connection Type | Solderless Wire Wrap (18 to 30 AWG) |
Alarm Rating | DC 30W/AC 50VA |
Standards | |
Safety Type | Listed |
Safety Approvals | UL 60950-1/UL 1801/CSA C22.2 No.60950-1/EN 60950-1/IEC 60950-1 |
Telcordia Approvals | NEBS Level 3 (GR-63/GR-1089) |
CLEI Code | PWPYADBRRA |
Downloads | |
Datasheet | 7873001211-A.pdf |
Installation Manual | INS-787XXXXXXX.pdf |