Front Access GMT Fuse Panel, Outside Plant Wall Mount, 10 Positions, Stud Input, Set Screw Output, -/+12-24V DC

Front Access GMT Fuse Panel, Outside Plant Wall Mount, 10 Positions, Stud Input, Set Screw Output, -/+12-24V DC
Click on the image above to zoom.
Part #: 7473121032
Bus Rating:
100 Amp
Number of Positions:
10 GMT
Max Fuse/Breaker:
15 Amp
Mechanical
Dimensions 5.5 In. [139.7mm] W x 3.38 In. [85.85mm] H x 1.34 In. [34mm] D
Rack Spaces 1U
Mounting Wall Mount
Offset MTG Positions Flush
Finish Black Textured Powder Coat
Packaging
Packaged Width 4 In. [10.16cm]
Packaged Length 6 In. [15.24cm]
Packaged Depth 4 In. [10.16cm]
Electrical
Nominal Voltage -/+12-24V DC
Voltage Range -/+10-30V DC
Number of Buses 1
Bus Rating 100 Amp
Max. Interrupt Device 125 Amps
Number of Positions 10 GMT
Max Fuse/Breaker 15 Amp
Max Continuous Load 10.5 Amps
Power Dissipation (Fully Loaded) 12.9 Watts max
Fuse/Breaker Type GMT
Extras
Load Sharing NO
Filtered NO
Volt/Current Meter NO
Connections
Input Type 2 Hole Compression Lugs, 1/4 In. x 5/8 In. Spacing
Input Wire Range Up to 2 AWG
Max. Terminal Width 0.625 In. max
Output Type Set Screw Output
Output Wire Range 12 to 22 AWG
Max. Terminal Width (Output) No Terminals Required
Chassis Ground Type Ground to mountIng hardware
Ground Wire Range Up to 6 AWG
Environmental
Short Term. Op. Temp -40° C to +70° C
Max. Ambient Up to 65° C
Storage Temperature -40° C to +70° C
Humidity Range 0 to 95% non-condensIng
Alarming
Alarm Indicators GMT arm flips down when fuse operates
Alarm Functions Form C Relay Contacts for Remote Fuse Fail Indication
Connection Type Set Screw (12 to 22 AWG)
Alarm Rating DC 30W/AC 50VA
Standards
Safety Type Listed
Safety Approvals UL 60950-1/UL 1801/CSA C22.2 No.60950-1/EN 60950-1/IEC 60950-1
Telcordia Approvals NEBS Level 3 (GR-63/GR-1089) and GR-3108 Class 3 (w/o salt fog testIng)
CLEI Code PWFYAS28RA
Downloads
Datasheet 7473121032.pdf
Installation Manual INS-7473121031.pdf
Datasheet: 7473121032.pdf
Installation Manual: INS-7473121031.pdf

Description

GMT, Outside Plant, Wall Mount, Stud Input, Set Screw Output, -/+12-24V DC

Specification

Mechanical
Dimensions 5.5 In. [139.7mm] W x 3.38 In. [85.85mm] H x 1.34 In. [34mm] D
Rack Spaces 1U
Mounting Wall Mount
Offset MTG Positions Flush
Finish Black Textured Powder Coat
Packaging
Packaged Width 4 In. [10.16cm]
Packaged Length 6 In. [15.24cm]
Packaged Depth 4 In. [10.16cm]
Electrical
Nominal Voltage -/+12-24V DC
Voltage Range -/+10-30V DC
Number of Buses 1
Bus Rating 100 Amp
Max. Interrupt Device 125 Amps
Number of Positions 10 GMT
Max Fuse/Breaker 15 Amp
Max Continuous Load 10.5 Amps
Power Dissipation (Fully Loaded) 12.9 Watts max
Fuse/Breaker Type GMT
Extras
Load Sharing NO
Filtered NO
Volt/Current Meter NO
Connections
Input Type 2 Hole Compression Lugs, 1/4 In. x 5/8 In. Spacing
Input Wire Range Up to 2 AWG
Max. Terminal Width 0.625 In. max
Output Type Set Screw Output
Output Wire Range 12 to 22 AWG
Max. Terminal Width (Output) No Terminals Required
Chassis Ground Type Ground to mountIng hardware
Ground Wire Range Up to 6 AWG
Environmental
Short Term. Op. Temp -40° C to +70° C
Max. Ambient Up to 65° C
Storage Temperature -40° C to +70° C
Humidity Range 0 to 95% non-condensIng
Alarming
Alarm Indicators GMT arm flips down when fuse operates
Alarm Functions Form C Relay Contacts for Remote Fuse Fail Indication
Connection Type Set Screw (12 to 22 AWG)
Alarm Rating DC 30W/AC 50VA
Standards
Safety Type Listed
Safety Approvals UL 60950-1/UL 1801/CSA C22.2 No.60950-1/EN 60950-1/IEC 60950-1
Telcordia Approvals NEBS Level 3 (GR-63/GR-1089) and GR-3108 Class 3 (w/o salt fog testIng)
CLEI Code PWFYAS28RA