Front Access TPA Fuse Panel, 4/4 Position, Stud Input, Barrier Strip Output, Power and Fuse Fail Alarm, -/+24-48V DC

Front Access TPA Fuse Panel, 4/4 Position, Stud Input, Barrier Strip Output, Power and Fuse Fail Alarm, -/+24-48V DC
Click on the image above to zoom.
Part #: 7476101001
Bus Rating:
150 Amps
Number of Positions:
4 TPA’s /side
Max Fuse/Breaker:
50 Amp
Mechanical
Dimensions 19 In. [482.6mm] W x 3.5 In. [88.9mm] H x 6.625 In. [168.28mm] D
Rack Spaces 2U
Mounting Universal, 19 or 23 Inch, WECO or EIA, Wall-Mountable
Offset MTG Positions Front or Rear Flush, 2.835 In. Offset
Finish Black Textured Powder Coat
Packaging
Packaged Width 16 In. [40.64cm]
Packaged Length 23 In. [58.42cm]
Packaged Depth 5.5 In. [13.97cm]
Electrical
Nominal Voltage -/+24-48V DC
Voltage Range -/+19-60V DC
Number of Buses 2
Bus Rating 150 Amps
Max. Interrupt Device 175 Amps
Number of Positions 4 TPA’s /side
Max Fuse/Breaker 50 Amp
Max Continuous Load 40 Amps
Power Dissipation (Fully Loaded) 35.7 Watts max
Fuse/Breaker Type TPA
Extras
Load Sharing NO
Filtered NO
Volt/Current Meter NO
Connections
Input Type 2 Hole Compression Lugs, 1/4 In. x 5/8 In. Spacing
Input Wire Range Up to 2/0 AWG
Max. Terminal Width 0.64 In. max
Output Type Barrier Strip Output
Output Wire Range 6 to 22 AWG
Max. Terminal Width (Output) 0.500 In. max
Chassis Ground Type 2 Hole Compression Lugs, 1/4 In. Stud x 5/8 In. Spacing
Ground Wire Range 6 AWG lug supplied with panel
Environmental
Short Term. Op. Temp -5° C to +55° C
Max. Ambient Up to 50° C
Storage Temperature -40° C to +70° C
Humidity Range 0 to 95% non-condensIng
Alarming
Alarm Indicators Green (Power)/Red (Alarm)
Alarm Functions Form C Relay Contacts for Remote Fuse and Power Fail Indication
Connection Type Solderless Wire Wrap (18 to 30 AWG)
Alarm Rating DC 30W/AC 50VA
Standards
Safety Type Listed
Safety Approvals UL 60950-1/UL 1801/CSA C22.2 No.60950-1/EN 60950-1/IEC 60950-1
Telcordia Approvals NEBS Level 3 (GR-63/GR-1089)
CLEI Code --
Downloads
Datasheet 7476101001.pdf
Installation Manual INS-747XXXXXXX.pdf
Datasheet: 7476101001.pdf
Installation Manual: INS-747XXXXXXX.pdf

Description

TPA, Stud Input, Barrier Strip Output, Power and Fuse Fail Alarm, -/+24-48V DC, Learn More…

Specification

Mechanical
Dimensions 19 In. [482.6mm] W x 3.5 In. [88.9mm] H x 6.625 In. [168.28mm] D
Rack Spaces 2U
Mounting Universal, 19 or 23 Inch, WECO or EIA, Wall-Mountable
Offset MTG Positions Front or Rear Flush, 2.835 In. Offset
Finish Black Textured Powder Coat
Packaging
Packaged Width 16 In. [40.64cm]
Packaged Length 23 In. [58.42cm]
Packaged Depth 5.5 In. [13.97cm]
Electrical
Nominal Voltage -/+24-48V DC
Voltage Range -/+19-60V DC
Number of Buses 2
Bus Rating 150 Amps
Max. Interrupt Device 175 Amps
Number of Positions 4 TPA’s /side
Max Fuse/Breaker 50 Amp
Max Continuous Load 40 Amps
Power Dissipation (Fully Loaded) 35.7 Watts max
Fuse/Breaker Type TPA
Extras
Load Sharing NO
Filtered NO
Volt/Current Meter NO
Connections
Input Type 2 Hole Compression Lugs, 1/4 In. x 5/8 In. Spacing
Input Wire Range Up to 2/0 AWG
Max. Terminal Width 0.64 In. max
Output Type Barrier Strip Output
Output Wire Range 6 to 22 AWG
Max. Terminal Width (Output) 0.500 In. max
Chassis Ground Type 2 Hole Compression Lugs, 1/4 In. Stud x 5/8 In. Spacing
Ground Wire Range 6 AWG lug supplied with panel
Environmental
Short Term. Op. Temp -5° C to +55° C
Max. Ambient Up to 50° C
Storage Temperature -40° C to +70° C
Humidity Range 0 to 95% non-condensIng
Alarming
Alarm Indicators Green (Power)/Red (Alarm)
Alarm Functions Form C Relay Contacts for Remote Fuse and Power Fail Indication
Connection Type Solderless Wire Wrap (18 to 30 AWG)
Alarm Rating DC 30W/AC 50VA
Standards
Safety Type Listed
Safety Approvals UL 60950-1/UL 1801/CSA C22.2 No.60950-1/EN 60950-1/IEC 60950-1
Telcordia Approvals NEBS Level 3 (GR-63/GR-1089)
CLEI Code --
Downloads
Datasheet 7476101001.pdf
Installation Manual INS-747XXXXXXX.pdf