Optimum Value Breaker Panel, 8 Positions, Stud Input, Barrier Strip Output, -/+24-48V DC, 19' Wide, Breakers Separate

Optimum Value Breaker Panel, 8 Positions, Stud Input, Barrier Strip Output, -/+24-48V DC, 19' Wide, Breakers Separate
Click on the image above to zoom.
Part #: 9075101001
Bus Rating:
100 Amps
Number of Positions:
8 Breaker
Max Fuse/Breaker:
30 Amp
Qty:  
Mechanical
Dimensions 19 In. [482.6mm] W x 1.75 In. [44.45mm] H x 3.25 In. [82.55mm] D
Rack Spaces 1U
Mounting 19 In. WECO/EIA. 23 inch Adapter Bracket Kits available.
Offset MTG Positions Flush (Swing Hinges available)
Finish Black Textured Powder Coat
Packaging
Packaged Width 8 In. [20.32cm]
Packaged Length 23 In. [58.42cm]
Packaged Depth 3.5 In. [8.89cm]
Electrical
Nominal Voltage -/+24-48V DC
Voltage Range -/+19-60V DC
Number of Buses 1
Bus Rating 100 Amps
Max. Interrupt Device 125 Amps
Number of Positions 8 Breaker
Max Fuse/Breaker 30 Amp
Max Continuous Load 24 Amps
Power Dissipation (Fully Loaded) 21 Watts max
Fuse/Breaker Type Breakers
Extras
Load Sharing NO
Filtered NO
Volt/Current Meter NO
Connections
Input Type 2 Hole Compression Lugs, 1/4 In. x 5/8 In. Spacing
Input Wire Range Up to 2/0 AWG
Max. Terminal Width 0.625 In. max
Output Type Barrier Strip Output
Output Wire Range 10 to 22 AWG
Max. Terminal Width (Output) 0.33 In. max
Chassis Ground Type 2 Hole Compression Lugs, 1/4 In. Stud x 5/8 In. Spacing
Ground Wire Range 6 AWG lug supplied with panel
Environmental
Short Term. Op. Temp -5° C to +55° C
Max. Ambient Up to 25° C
Storage Temperature -40° C to +70° C
Humidity Range 0 to 95% non-condensIng
Alarming
Alarm Indicators One Bi-color LED per Bus, Green for Power, Red for Alarm or Breaker Off
Alarm Functions Form C Relay Contacts for Remote Breaker Fail or Off Indication
Connection Type Set Screw Output (12 to 22 AWG)
Alarm Rating DC 30W/AC 50VA
Standards
Safety Type Recognized
Safety Approvals UL 60950-1/UL 1801/CSA C22.2 No.60950-1/EN 60950-1/IEC 60950-1
Telcordia Approvals NEBS Level 3 (GR-63/GR-1089)
CLEI Code --
Downloads
Datasheet 9075101001.pdf
Installation Manual INS-907XXXXXXX.pdf
Special
Featured Product Yes
Datasheet: 9075101001.pdf
Installation Manual: INS-907XXXXXXX.pdf

Description

Stud In, Barrier Strip Out, Power Indication, Breaker Trip Alarm, -/+24-48V DC, 19' Wide, Learn More…

Specification

Mechanical
Dimensions 19 In. [482.6mm] W x 1.75 In. [44.45mm] H x 3.25 In. [82.55mm] D
Rack Spaces 1U
Mounting 19 In. WECO/EIA. 23 inch Adapter Bracket Kits available.
Offset MTG Positions Flush (Swing Hinges available)
Finish Black Textured Powder Coat
Packaging
Packaged Width 8 In. [20.32cm]
Packaged Length 23 In. [58.42cm]
Packaged Depth 3.5 In. [8.89cm]
Electrical
Nominal Voltage -/+24-48V DC
Voltage Range -/+19-60V DC
Number of Buses 1
Bus Rating 100 Amps
Max. Interrupt Device 125 Amps
Number of Positions 8 Breaker
Max Fuse/Breaker 30 Amp
Max Continuous Load 24 Amps
Power Dissipation (Fully Loaded) 21 Watts max
Fuse/Breaker Type Breakers
Extras
Load Sharing NO
Filtered NO
Volt/Current Meter NO
Connections
Input Type 2 Hole Compression Lugs, 1/4 In. x 5/8 In. Spacing
Input Wire Range Up to 2/0 AWG
Max. Terminal Width 0.625 In. max
Output Type Barrier Strip Output
Output Wire Range 10 to 22 AWG
Max. Terminal Width (Output) 0.33 In. max
Chassis Ground Type 2 Hole Compression Lugs, 1/4 In. Stud x 5/8 In. Spacing
Ground Wire Range 6 AWG lug supplied with panel
Environmental
Short Term. Op. Temp -5° C to +55° C
Max. Ambient Up to 25° C
Storage Temperature -40° C to +70° C
Humidity Range 0 to 95% non-condensIng
Alarming
Alarm Indicators One Bi-color LED per Bus, Green for Power, Red for Alarm or Breaker Off
Alarm Functions Form C Relay Contacts for Remote Breaker Fail or Off Indication
Connection Type Set Screw Output (12 to 22 AWG)
Alarm Rating DC 30W/AC 50VA
Standards
Safety Type Recognized
Safety Approvals UL 60950-1/UL 1801/CSA C22.2 No.60950-1/EN 60950-1/IEC 60950-1
Telcordia Approvals NEBS Level 3 (GR-63/GR-1089)
CLEI Code --
Downloads
Datasheet 9075101001.pdf
Installation Manual INS-907XXXXXXX.pdf
Special
Featured Product Yes