GMT Fuse Panel, 10 Positions, Set Screw Input and Output, Power and Fuse Fail Alarm, -/+12-24V DC

GMT Fuse Panel, 10 Positions, Set Screw Input and Output, Power and Fuse Fail Alarm, -/+12-24V DC
Click on the image above to zoom.
Part #: 7071211002
Bus Rating:
65 Amps
Number of Positions:
10 GMT
Max Fuse/Breaker:
15 Amp
Mechanical
Dimensions 19 In. [482.6mm] W x 1.75 In. [44.45mm] H x 11.25 In. [285.75mm] D
Rack Spaces 1U
Mounting Universal, 19 or 23 Inch, WECO or EIA
Offset MTG Positions Flush, 4 In. or 5 In. Offset
Finish Black Textured Powder Coat
Packaging
Packaged Width 16 In. [40.64cm]
Packaged Length 23 In. [58.42cm]
Packaged Depth 3.5 In. [8.89cm]
Electrical
Nominal Voltage -/+12-24V DC
Voltage Range -/+10-30V DC
Number of Buses 1
Bus Rating 65 Amps
Max. Interrupt Device 80 Amps
Number of Positions 10 GMT
Max Fuse/Breaker 15 Amp
Max Continuous Load 10.5 Amps
Power Dissipation (Fully Loaded) 11.18 Watts max
Fuse/Breaker Type GMT
Extras
Load Sharing NO
Filtered NO
Volt/Current Meter NO
Connections
Input Type Set Screw Input
Input Wire Range Up to 1 AWG
Max. Terminal Width No Terminals Required
Output Type Set Screw Output
Output Wire Range 12 to 22 AWG
Max. Terminal Width (Output) No Terminals Required
Chassis Ground Type 2 Hole Compression Lugs, 1/4 In. Stud x 1 In. Spacing
Ground Wire Range 6 AWG lug supplied with panel
Environmental
Short Term. Op. Temp -40° C to +70° C
Max. Ambient Up to 65° C
Storage Temperature -40° C to +70° C
Humidity Range 0 to 95% non-condensIng
Alarming
Alarm Indicators Green (Power)/Red (Alarm)
Alarm Functions Form C Relay Contacts for Remote Fuse and Power Fail Indication
Connection Type Solderless Wire Wrap (18 to 30 AWG)
Alarm Rating DC 30W/AC 50VA
Standards
Safety Type Listed
Safety Approvals UL 60950-1/UL 1801/CSA C22.2 No.60950-1/EN 60950-1/IEC 60950-1
Telcordia Approvals NEBS Level 3 (GR-63/GR-1089) and GR-3108 Class 3 (w/o salt fog testIng)
CLEI Code --
Downloads
Datasheet 7071211002.pdf
Installation Manual INS-707XXXXXXX.pdf
Datasheet: 7071211002.pdf
Installation Manual: INS-707XXXXXXX.pdf

Description

Set Screw Input and Output, Power and Fuse Fail Alarm, -/+12-24V DC, Learn More…

Specification

Mechanical
Dimensions 19 In. [482.6mm] W x 1.75 In. [44.45mm] H x 11.25 In. [285.75mm] D
Rack Spaces 1U
Mounting Universal, 19 or 23 Inch, WECO or EIA
Offset MTG Positions Flush, 4 In. or 5 In. Offset
Finish Black Textured Powder Coat
Packaging
Packaged Width 16 In. [40.64cm]
Packaged Length 23 In. [58.42cm]
Packaged Depth 3.5 In. [8.89cm]
Electrical
Nominal Voltage -/+12-24V DC
Voltage Range -/+10-30V DC
Number of Buses 1
Bus Rating 65 Amps
Max. Interrupt Device 80 Amps
Number of Positions 10 GMT
Max Fuse/Breaker 15 Amp
Max Continuous Load 10.5 Amps
Power Dissipation (Fully Loaded) 11.18 Watts max
Fuse/Breaker Type GMT
Extras
Load Sharing NO
Filtered NO
Volt/Current Meter NO
Connections
Input Type Set Screw Input
Input Wire Range Up to 1 AWG
Max. Terminal Width No Terminals Required
Output Type Set Screw Output
Output Wire Range 12 to 22 AWG
Max. Terminal Width (Output) No Terminals Required
Chassis Ground Type 2 Hole Compression Lugs, 1/4 In. Stud x 1 In. Spacing
Ground Wire Range 6 AWG lug supplied with panel
Environmental
Short Term. Op. Temp -40° C to +70° C
Max. Ambient Up to 65° C
Storage Temperature -40° C to +70° C
Humidity Range 0 to 95% non-condensIng
Alarming
Alarm Indicators Green (Power)/Red (Alarm)
Alarm Functions Form C Relay Contacts for Remote Fuse and Power Fail Indication
Connection Type Solderless Wire Wrap (18 to 30 AWG)
Alarm Rating DC 30W/AC 50VA
Standards
Safety Type Listed
Safety Approvals UL 60950-1/UL 1801/CSA C22.2 No.60950-1/EN 60950-1/IEC 60950-1
Telcordia Approvals NEBS Level 3 (GR-63/GR-1089) and GR-3108 Class 3 (w/o salt fog testIng)
CLEI Code --
Downloads
Datasheet 7071211002.pdf
Installation Manual INS-707XXXXXXX.pdf